Electrode and Cell Potentials Quiz
The question sheet
Reveal any answer as you study-
How is the standard cell potential defined?
- E°anode − E°cathode
- E°cathode + E°anode
- E°cathode − E°anode
- E°anode × E°cathode
Reveal answer
Answer: E°cathode − E°anode
Source evidence
PDF page 915: wire in an aqueous solution of lead(II) ions yields no reaction. The two species, Ag (aq) and Pb (aq), thus show a distinct difference in their redox activity towards copper: the silver ion spontaneously oxidized copper, but the lead ion did not. Electrochemical cells permit this relative redox activity to be quantified by an easily measured property, potential. This property is more commonly called voltage when referenced in regard to electrical applications, and it is a measure of energy accompanying the transfer of charge. Potentials are measured in the volt unit, defined as one joule of energy per one coulomb of charge, V = J/C. When measured for purposes of electrochemistry, a potential reflects the driving force for a specific type of charge transfer process, namely, the transfer of electrons between redox reactants. Considering the nature of potential in this context, it is clear that the potential of a single half-cell or a single electrode can’t be measured; “transfer” of electrons requires both a donor and recipient, in this case a reductant and an oxidant, respectively. Instead, a half-cell potential may only be assessed relative to that of another half-cell. It is only the difference in potential between two half-cells that may be measured, and these measured potentials are called cell potentials, Ecell, defined as E = E − E cell cathode anode where Ecathode and Eanode are the potentials of two different half-cells functioning as specified in the subscripts. As for other thermodynamic quantities, the standard cell potential, E°cell, is a cell potential measured when both half-cells are under standard-state conditions (1 M concentrations, 1 bar pressures, 298 K): ° ° ° E = E − E cell cathode anode To simplify the collection and sharing of potential data for half-reactions, the scientific community has designated one particular half-cell to serve as a universal reference for cell potential measurements, assigning it a potential of exactly 0 V. This half-cell is the standard hydrogen electrode (SHE) and it is based on half-reaction below: + − 2H (aq) + 2e ⟶ H (g) 2 +
-
What is the unit of potential and its definition?
- Ohm, one volt per amp
- Volt, one joule per coulomb
- Watt, one joule per second
- Amp, one coulomb per second
Reveal answer
Answer: Volt, one joule per coulomb
Source evidence
PDF page 915: wire in an aqueous solution of lead(II) ions yields no reaction. The two species, Ag (aq) and Pb (aq), thus show a distinct difference in their redox activity towards copper: the silver ion spontaneously oxidized copper, but the lead ion did not. Electrochemical cells permit this relative redox activity to be quantified by an easily measured property, potential. This property is more commonly called voltage when referenced in regard to electrical applications, and it is a measure of energy accompanying the transfer of charge. Potentials are measured in the volt unit, defined as one joule of energy per one coulomb of charge, V = J/C. When measured for purposes of electrochemistry, a potential reflects the driving force for a specific type of charge transfer process, namely, the transfer of electrons between redox reactants. Considering the nature of potential in this context, it is clear that the potential of a single half-cell or a single electrode can’t be measured; “transfer” of electrons requires both a donor and recipient, in this case a reductant and an oxidant, respectively. Instead, a half-cell potential may only be assessed relative to that of another half-cell. It is only the difference in potential between two half-cells that may be measured, and these measured potentials are called cell potentials, Ecell, defined as E = E − E cell cathode anode where Ecathode and Eanode are the potentials of two different half-cells functioning as specified in the subscripts. As for other thermodynamic quantities, the standard cell potential, E°cell, is a cell potential measured when both half-cells are under standard-state conditions (1 M concentrations, 1 bar pressures, 298 K): ° ° ° E = E − E cell cathode anode To simplify the collection and sharing of potential data for half-reactions, the scientific community has designated one particular half-cell to serve as a universal reference for cell potential measurements, assigning it a potential of exactly 0 V. This half-cell is the standard hydrogen electrode (SHE) and it is based on half-reaction below: + − 2H (aq) + 2e ⟶ H (g) 2 +
-
What potential is assigned to the standard hydrogen electrode?
- −0.76 V
- +1.00 V
- +0.337 V
- 0 V exactly
Reveal answer
Answer: 0 V exactly
Source evidence
PDF page 915: wire in an aqueous solution of lead(II) ions yields no reaction. The two species, Ag (aq) and Pb (aq), thus show a distinct difference in their redox activity towards copper: the silver ion spontaneously oxidized copper, but the lead ion did not. Electrochemical cells permit this relative redox activity to be quantified by an easily measured property, potential. This property is more commonly called voltage when referenced in regard to electrical applications, and it is a measure of energy accompanying the transfer of charge. Potentials are measured in the volt unit, defined as one joule of energy per one coulomb of charge, V = J/C. When measured for purposes of electrochemistry, a potential reflects the driving force for a specific type of charge transfer process, namely, the transfer of electrons between redox reactants. Considering the nature of potential in this context, it is clear that the potential of a single half-cell or a single electrode can’t be measured; “transfer” of electrons requires both a donor and recipient, in this case a reductant and an oxidant, respectively. Instead, a half-cell potential may only be assessed relative to that of another half-cell. It is only the difference in potential between two half-cells that may be measured, and these measured potentials are called cell potentials, Ecell, defined as E = E − E cell cathode anode where Ecathode and Eanode are the potentials of two different half-cells functioning as specified in the subscripts. As for other thermodynamic quantities, the standard cell potential, E°cell, is a cell potential measured when both half-cells are under standard-state conditions (1 M concentrations, 1 bar pressures, 298 K): ° ° ° E = E − E cell cathode anode To simplify the collection and sharing of potential data for half-reactions, the scientific community has designated one particular half-cell to serve as a universal reference for cell potential measurements, assigning it a potential of exactly 0 V. This half-cell is the standard hydrogen electrode (SHE) and it is based on half-reaction below: + − 2H (aq) + 2e ⟶ H (g) 2 +
-
A typical SHE uses an inert electrode made of:
- Zinc
- Copper
- Platinum
- Silver
Reveal answer
Answer: Platinum
Source evidence
PDF page 915: A typical SHE contains an inert platinum electrode immersed in precisely 1 M aqueous H and a stream of bubbling H2 gas at 1 bar pressure, all maintained at a temperature of 298 K (see Figure 17.5).
-
Standard-state conditions for a cell potential are:
- 1 M, 1 bar, 298 K
- 2 M, 2 bar, 300 K
- 1 M, 10 bar, 373 K
- 0.1 M, 1 atm, 273 K
Reveal answer
Answer: 1 M, 1 bar, 298 K
Source evidence
PDF page 915: wire in an aqueous solution of lead(II) ions yields no reaction. The two species, Ag (aq) and Pb (aq), thus show a distinct difference in their redox activity towards copper: the silver ion spontaneously oxidized copper, but the lead ion did not. Electrochemical cells permit this relative redox activity to be quantified by an easily measured property, potential. This property is more commonly called voltage when referenced in regard to electrical applications, and it is a measure of energy accompanying the transfer of charge. Potentials are measured in the volt unit, defined as one joule of energy per one coulomb of charge, V = J/C. When measured for purposes of electrochemistry, a potential reflects the driving force for a specific type of charge transfer process, namely, the transfer of electrons between redox reactants. Considering the nature of potential in this context, it is clear that the potential of a single half-cell or a single electrode can’t be measured; “transfer” of electrons requires both a donor and recipient, in this case a reductant and an oxidant, respectively. Instead, a half-cell potential may only be assessed relative to that of another half-cell. It is only the difference in potential between two half-cells that may be measured, and these measured potentials are called cell potentials, Ecell, defined as E = E − E cell cathode anode where Ecathode and Eanode are the potentials of two different half-cells functioning as specified in the subscripts. As for other thermodynamic quantities, the standard cell potential, E°cell, is a cell potential measured when both half-cells are under standard-state conditions (1 M concentrations, 1 bar pressures, 298 K): ° ° ° E = E − E cell cathode anode To simplify the collection and sharing of potential data for half-reactions, the scientific community has designated one particular half-cell to serve as a universal reference for cell potential measurements, assigning it a potential of exactly 0 V. This half-cell is the standard hydrogen electrode (SHE) and it is based on half-reaction below: + − 2H (aq) + 2e ⟶ H (g) 2 +
-
In defining electrode potential EX, half-cell X acts as the:
- Cathode
- SHE
- Anode
- Reference
Reveal answer
Answer: Cathode
Source evidence
PDF page 916: The assigned potential of the SHE permits the definition of a conveniently measured potential for a single half-cell. The electrode potential (EX) for a half-cell X is defined as the potential measured for a cell comprised of X acting as cathode and the SHE acting as anode: E = E − E X SHE cell E = 0 V (defined SHE E = E X cell When the half-cell X is under standard-state conditions, its potential is the standard electrode potential, E°X. Since the definition of cell potential requires the half-cells function as cathodes, these potentials are sometimes called standard reduction potentials. This approach to measuring electrode potentials is illustrated in Figure 17.6, which depicts a cell comprised of an SHE connected to a copper(II)/copper(0) half-cell under standard-state conditions. A voltmeter in the external circuit allows measurement of the potential difference between the two half-cells. Since the Cu half-cell is designated as the cathode in the definition of cell potential, it is connected to the red (positive) input of the voltmeter, while the designated SHE anode is connected to the black (negative) input. These connections insure that the sign of the measured potential will be consistent with the sign conventions of electrochemistry per the various definitions discussed above. A cell potential of +0.337 V is measured, and so ° ° E = E = +0.337 V Cu cell Tabulations of E° values for other half-cells measured in a similar fashion are available as reference literature to permit calculations of cell potentials and the prediction of the spontaneity of redox processes.
-
Because they are defined with X as cathode, electrode potentials are also called:
- Cell potentials
- Standard oxidation potentials
- Anode potentials
- Standard reduction potentials
Reveal answer
Answer: Standard reduction potentials
Source evidence
PDF page 916: The assigned potential of the SHE permits the definition of a conveniently measured potential for a single half-cell. The electrode potential (EX) for a half-cell X is defined as the potential measured for a cell comprised of X acting as cathode and the SHE acting as anode: E = E − E X SHE cell E = 0 V (defined SHE E = E X cell When the half-cell X is under standard-state conditions, its potential is the standard electrode potential, E°X. Since the definition of cell potential requires the half-cells function as cathodes, these potentials are sometimes called standard reduction potentials. This approach to measuring electrode potentials is illustrated in Figure 17.6, which depicts a cell comprised of an SHE connected to a copper(II)/copper(0) half-cell under standard-state conditions. A voltmeter in the external circuit allows measurement of the potential difference between the two half-cells. Since the Cu half-cell is designated as the cathode in the definition of cell potential, it is connected to the red (positive) input of the voltmeter, while the designated SHE anode is connected to the black (negative) input. These connections insure that the sign of the measured potential will be consistent with the sign conventions of electrochemistry per the various definitions discussed above. A cell potential of +0.337 V is measured, and so ° ° E = E = +0.337 V Cu cell Tabulations of E° values for other half-cells measured in a similar fashion are available as reference literature to permit calculations of cell potentials and the prediction of the spontaneity of redox processes.
-
What standard electrode potential was measured for the Cu(II)/Cu half-cell?
- +0.7996 V
- −0.34 V
- 0 V
- +0.337 V
Reveal answer
Answer: +0.337 V
Source evidence
PDF page 916: The assigned potential of the SHE permits the definition of a conveniently measured potential for a single half-cell. The electrode potential (EX) for a half-cell X is defined as the potential measured for a cell comprised of X acting as cathode and the SHE acting as anode: E = E − E X SHE cell E = 0 V (defined SHE E = E X cell When the half-cell X is under standard-state conditions, its potential is the standard electrode potential, E°X. Since the definition of cell potential requires the half-cells function as cathodes, these potentials are sometimes called standard reduction potentials. This approach to measuring electrode potentials is illustrated in Figure 17.6, which depicts a cell comprised of an SHE connected to a copper(II)/copper(0) half-cell under standard-state conditions. A voltmeter in the external circuit allows measurement of the potential difference between the two half-cells. Since the Cu half-cell is designated as the cathode in the definition of cell potential, it is connected to the red (positive) input of the voltmeter, while the designated SHE anode is connected to the black (negative) input. These connections insure that the sign of the measured potential will be consistent with the sign conventions of electrochemistry per the various definitions discussed above. A cell potential of +0.337 V is measured, and so ° ° E = E = +0.337 V Cu cell Tabulations of E° values for other half-cells measured in a similar fashion are available as reference literature to permit calculations of cell potentials and the prediction of the spontaneity of redox processes.
-
The stronger oxidant is the species with the:
- Most negative electrode potential
- Zero potential
- Lowest table position
- Greater standard electrode potential
Reveal answer
Answer: Greater standard electrode potential
Source evidence
PDF page 919: (“strength”) with which aqueous Ag and Pb ions oxidize Cu under standard conditions, the stronger oxidant is the one exhibiting the greater standard electrode potential, E°. Since by convention electrode potentials are for reduction processes, an increased value of E° corresponds to an increased driving force behind the reduction of the species (hence increased effectiveness of its action as an oxidizing agent on some other species). Negative values for electrode potentials are simply a consequence of assigning a value of 0 V to the SHE, indicating the reactant of the half-reaction is a weaker oxidant than aqueous hydrogen ions. Applying this logic to the numerically ordered listing of standard electrode potentials in Table 17.1 shows this listing
-
A negative electrode potential indicates the reactant is:
- A weaker oxidant than H+
- A stronger oxidant than H+
- A perfect reductant
- Unreactive
Reveal answer
Answer: A weaker oxidant than H+
Source evidence
PDF page 919: (“strength”) with which aqueous Ag and Pb ions oxidize Cu under standard conditions, the stronger oxidant is the one exhibiting the greater standard electrode potential, E°. Since by convention electrode potentials are for reduction processes, an increased value of E° corresponds to an increased driving force behind the reduction of the species (hence increased effectiveness of its action as an oxidizing agent on some other species). Negative values for electrode potentials are simply a consequence of assigning a value of 0 V to the SHE, indicating the reactant of the half-reaction is a weaker oxidant than aqueous hydrogen ions. Applying this logic to the numerically ordered listing of standard electrode potentials in Table 17.1 shows this listing
-
In Table 17.1, ordering by numerical E° gives an order of:
- Decreasing oxidizing strength
- Alphabetical order
- Increasing reducing strength only
- Random arrangement
Reveal answer
Answer: Decreasing oxidizing strength
Source evidence
PDF page 920: to be likewise in order of the oxidizing strength of the half-reaction’s reactant species, decreasing from strongest oxidant (most positive E°) to weakest oxidant (most negative E°). Predictions regarding the spontaneity of redox reactions under standard state conditions can then be easily made by simply comparing the relative positions of their
-
A redox reaction is predicted spontaneous when the oxidant's entry is:
- Above the reductant's entry
- Missing from the table
- Below the reductant's entry
- Equal to the reductant's
Reveal answer
Answer: Above the reductant's entry
Source evidence
PDF page 920: entry is above the reductant’s entry is predicted to be spontaneous. Reconsideration of the two redox reactions in Example 17.4 provides support for this fact. The entry for the silver(I)/silver(0) half-reaction is above that for the copper(II)/copper(0) half-reaction, and so the oxidation of Cu by
PDF page 920: table entries. By definition, E°cell is positive when E°cathode > E°anode, and so any redox reaction in which the oxidant’s
Chemistry 2e
Chemistry 2e by OpenStax, used under CC BY 4.0. Changes made by Stratacademy.
Make your own — free
Turn any notes into a game in under a minute. Free to start.